HABITAT cell

PreviousNext
image-brand

To find out more details, please fill in the request form below.

Ask for more information
+40 21 255 31 32

Description

HABITAT cell
The HABITAT cell control tower package is particularly suitable for HABITAT’s cell culture applications and is used to monitor and control the bioprocess. It includes the control unit with all connection options for gas supply, liquid addition, sensors and temperature control as well as a tablet for easy and clear operation of the bioreactor.

Control and monitoring
The bioprocess and all associated test parameters can be easily controlled and monitored via the tablet attached to the control unit and with the help of the intuitive and easy-to-use software. Depending on the type of cultivation, you can choose between the operating modes batch, fed-batch and perfusion/continuous. The new Chaotic Mixing function ensures faster and more effective mixing when required. The 10.4-inch tablet allows direct access to all actuators directly on the main screen. A clear calibration management, a diagram overview and the complete documentation of the process round off the operation. A software version that meets FDA CFR Part 11 requirements is available as an option.

Gas supply
Built in mass flow controllers for 4 separate gas lines (for N2, O2, air and CO2) ensure precise, individually adjustable gassing, ideally tailored to the needs of your cells. Flow rates of 0.01 - 2 l/min can be achieved.

Liquid supply
4 integrated Watson Marlow pumps, adjustable in direction and speed, give you the variability to pump in and pump out different liquids (like acid, base, anti-foam agent, feeding solutions).

Sensors
HABITAT cell enables the measurement of the following parameters by means of sensors:
• pH
• DO (dissolved oxygen)
• temperature
• filling level
• foam

Temperature control
The constant and precise temperature control during the cultivation is guaranteed by the heating sleeve, which is adapted to the respective vessel size. (Heating sleeve is included with the HABITAT cell vessel package).

All features at a glance
> compact, space-saving design, dimensions: 223 x 402 x 450 mm (WxDxH)
> large tablet for clear operation (10,4 inch)
> intuitive, easy-to-use software with a lot of functionalities.
> 4 integrated fast-load pumps (Watson Marlow)
> connectivity: USB, PC, RS232, ethernet, external signal input, external pump, single-use unit, thermostat
> data storage
> gas supply with 4 built-in mass flow controllers: e.g. for O2, Luft, N2, CO2
> Status LED display: direct error display by indicator light

Note: Only a control tower package and the separately available vessel package make up a functional unit.

Scope of delivery

    HABITAT cell S099
    Tablet with software for bioreactor
    HA.pl. Peltier cooling element

Technical Data

Controller Cell Growth
Operating mode timer, continuous and program operation
Display Tablet PC
Operation touch screen
Data memory size 32 GB
Auto restart after power failure yes
Ethernet interface yes
Single use reactor interface yes
Thermostat interface yes
Ext. pump interface yes
Gravimetric feeding yes
Exponential feeding yes
Biomass feeding yes, with CGQ BioR Sensor
OPC UA interface yes
Filter heater yes
LED light panel Accessory
Stirring motor yes
Calibration guide temperature yes
Calibration guide pH yes
Calibration guide pO2 yes
pH - temperature compensation yes
Mode hose filling yes
Stirrer control mode off, manual, profile, Cascade-pO2 control, chaotic
Speed range 1 - 2200 rpm
Speed deviation >= 100 rpm ±2 %
Speed deviation <= 100 rpm ±5 rpm
Speed display TFT
Reversible direction of rotation yes
Timer yes
Timer display TFT
Time setting range 1 - 120 min
Heating blanket yes
Heat output 250 W
Heat control TFT
Temperature control PID
Working temperature 5 - 80 °C
Connection for ext. temperature sensor PT1000
Temperature display yes
Temperature measuring range 0 - 100 °C
Temperature measurement resolution 0.1 K
Temperature control accuracy ±0.2 °C
Temperature limit min. 0 °C
Temperature limit max. 110 °C
pH measurement yes
pH control mode off, auto, profile
pH value display TFT
pH measuring range 0 - 14 pH
pH measurement resolution 0.01 pH
Accuracy of pH measurement ±0.02 pH
Set resolution pH value 0.01 pH
pH control accuracy ±0.05 pH
Conncetion for pO2 sensor yes
pO2 control mode off, manual, auto, profile
Measurement range pO2 min. 0 %sat
Measurement range pO2 max. 200 %sat
Resolution pO2 measurement 0.01 %sat
Accuracy of pO2 measurement ±0.3 %sat
pO2 control accuracy 0.3 %sat
Exhaust Gas Analyzer yes, with Blue Vary Sensor
OUR,CER,RQ calculation yes, with Blue Vary Sensor
RQ feeding yes, with Blue Vary Sensor
Digital pH sensor yes, with EasyFerm Bio Arc Sensor
Measuring Range min. digital pH 0 pH
Measuring Range max. digital pH 14 pH
Accuracy digital pH ±0.02 pH
Digital DO sensor yes, with OxyFerm FDA Arc
Measuring Range min. digital DO 0 %sat
Measuring Range max. digital DO 200 %sat
Accuracy digital DO ±2 %
Optical DO sensor yes, with VisiFerm RS485-ECS
Measuring Range min. optical DO 0 %sat
Measuring Range max. optical DO 300 %sat
Accuracy optical DO ±1 %
Biomass sensor yes, with CGQ BioR Sensor
Measuring Range min. Biomass 0.5 OD
Measuring Range max. Biomass 50 OD
Digital Redox / ORP sensor yes, with EasyFerm Plus ORP Arc
Measuring Range min. digital ORP -1500 mV
Measuring Range max. digital ORP 1500 mV
Digital biomass sensor yes, with Excell Sensor
Measuring Range min. digital biomass 0 AU
Measuring Range max. digital biomass 6 AU
Accuracy digital biomass ±1 %
Viable Cell Density Sensors yes, with Incyte Sensor
Measuring Range min. cell density 5 x 10^5 cells/mL
Measuring Range max. cell density 8 x 10^9 cells/mL
Accuracy cell density ±1 %
Gas in connection Air 6 mm
Gas out connection Air 6 mm
Gas in connection O2 6 mm
Gas out connection O2 6 mm
Gas in connection N2 6 mm
Gas out connection N2 6 mm
Gas in connection CO2 6 mm
Gas out connection CO2 6 mm
Aeration mode continuous & automatic
Display flowrate l/min, cc/min
Input pressure 200 - 3000 mbar
Pressure out min. 200 mbar
Pressure out max. 1000 mbar
Flowrate Air min. 1 cc/min
Flowrate Air max. 2000 cc/min
Flowrate O2 min. 1 cc/min
Flowrate O2 max. 2000 cc/min
Flowrate N2 min. 1 cc/min
Flowrate N2 max. 2000 cc/min
Flowrate CO2 min. 1 cc/min
Flowrate CO2 min. 2000 cc/min
Measuring and control accuracy of the gas control units ±2 % fsr
Peristaltic pump yes
Numbers of pump heads 4
Pump head function Acid, Base, AntiFoam, Level
Pump head Watson Marlow 114DV
Number of pump tubes 4
Number of pump rollers 4
Flow rate min. 0.3 ml/min
Flow rate max. 270 ml/min
Flow rate control accuracy ±0.3 ml/min
Pump Speed min. 33 rpm
Pump Speed max. 400 rpm
Pump reversible direction of rotation yes
Pump speed display TFT
Inner tube diameter min. 0.5 mm
Inner tube diameter max. 4.8 mm
Tube outer diamter min. 4.1 mm
Tube outer diamter max. 8.4 mm
Tube material Silicone
Tube hardness 50 - 60 Shore A
Dimensions (W x H x D) 224 x 624 x 405 mm
Weight 14 kg
Packing unit 1 pcs
Permissible ambient temperature 5 - 40 °C
Permissible relative humidity 80% (up to 31°C), decreasing linearly to max. 50 (@40°C)
Protection class according to DIN EN 60529 IP 20
RS 232 interface yes
USB interface yes
WiFi Interface yes
Voltage 100 - 240 V
Frequency 50/60 Hz
Power input 300 W
Power input max. 1100 W
Power input standby 10 W
Fuse 2x T5.0A 250V