Bioban Safety Cabinets

PreviousNext
image-brand

To find out more details, please fill in the request form below.

Ask for more information
+40 21 255 31 32

Description

BIOBAN cabinets produced by Steril are designed and manufactured to fulfil and satisfy the European Norm EN12469. 

Routinelly used in laboratory of microbiology, virology, haematology and cell culture.

Furthermore, used in innovative fields of scientific research and above all in the manipulation of:

•          Recombinant DNA

•          Oncogenic Virus

•          Pathogenic agents

For a correct use and application of the cabinet here described, it is necessary to refer to the appropriate standard norm and rules in force in the country where the cabinet is used.


Technical Specification

Back panel in stainless steel AISI 304L “2B” finishing, thickness 12/10.

Working surface in stainless steel AISI 304L “2B” finishing, divided in sectors removable and autoclavable (4 sectors for mod. 48 and 6 sectors for mod. 72), available both in perforated and solid version.

Sidewalls in toughened safety glass.

Front window made in toughened safety glass electrically driven, 2,5° slope for optimum ergonomic worker posture.

Lighting on working surface by means of fluorescent lighting fitted in non-contaminated area.

Minimum level of lighting 1.000 lux.

Construction structure in steel epoxy-polyester powder coated, resistant to the most common industrial disinfectants.

Ventilation system by means of n°1 motor blower dedicated to the one-way airflow in the working chamber, equal to 70% of the total involved air and to exhaust the remaining 30%.

The motor blower is centrifugal type, direct driven motor with double aspiration and protection factor IP55.

Air filtration, both recirculate and exhaust air by means of H14 HEPA filters with efficiency 99,995% MPPS as per EN 1822 (EU14 with efficiency 99,999% tested with DOP/DOS @ 0.3 ?m). Both filters will be tested with scanning method for integrity with DOP/DOS test.

UV germicidal lamp on back stainless steel panel.

 

Command and Controls

Air ventilation control by means of automatic regulation of the revolution velocity of the motor blower. One high-resolution flow rate volumetric device, directly interfaced to microprocessor, achieves the automatic regulation. The microprocessor guarantees the activity of the motor blower and controls the optimal function even in presence of effects caused by progressive clogging of the HEPA filters.

Alarm device optical (red signal light visible from working position and display message) and acoustic (buzzer) type, activated, at real time, by the microprocessor, showing the kind of alarm on a wide alpha numeric display.

 

Monitoring with alarms of the following parameters:

•          Exhaust flow rate out of the pre-set range;

•          Laminar air flow rate out of the pre-set range;

•          Failure of the motor blower;

•          Front window in wrong position;

 

Alpha numeric display showing:

•          Laminar air flow speed in m/s;

•          Date and time

•          Hours counters for cabinet life

•          UV Lamp run hours

•          HEPA filters run hours

•          Date of last HEPA filters change

•          Date of last service

•          Date of last power failure

•          Change language

•          Change password

•          Setting UV timer program

•          Setting MSC decontamination program

 

Standard features

•          Fluorescent lighting

•          Power socket 4A, IP 55 (internal back panel-right side).

•          DOP/DOS 100% test inlet hose-barb port (internal under worktop - left side)

•          3 holes (19 mm diameter) on both side windows (for fluid taps installation or other connections) with plastic caps.

•          UV germicidal lamp 30 W on back stainless steel panel wavelength 253.7 nm (UV-C).

 

 

GEMINI Vertical laminar airflow cabinets

Applications

Normally used in laboratory of microbiology, molecular biology and, furthermore, used in innovative fields of scientific research and above all in the manipulation of:

·         Quality Control in pharmaceutical and food industries

·         Micro mechanical assembly

·         DNA/RNA amplification and thermo-cycling

 

Technical specification

Back panel and working tray in stainless steel AISI 304L “2B” finishing, perforated.

Front window and side walls in toughened glass.

Lighting on working surface by means of 1 fluorescent lamps of 15W

Construction structure in steel epoxy-polyester powder coated, resistant to the most common industrial disinfectants.

Ventilation system by means of n°1 motor blower dedicated to the one-way airflow in the working chamber, equal to 95% of the total involved air and to exhaust the remaining 5%.

The motor blower is centrifugal type, direct driven motor with double aspiration and protection factor IP22.

Air filtration by means of HEPA “H14 type” filter (refer to DIN 24184 and BS 3928) with efficiency of 99,999% at 0,3 micron particles size with DOP/DOS test (as defined to EN1822).

Command and Controls

Air ventilation control by means of manual electronic regulation of the revolution velocity of the motor blower.

 

 

HELIOS Horizontal laminar airflow cabinets

Helios are horizontal laminar airflow cabinets produced by Steril and designed for the
situation where is requested the product protection from dangerous effects due
to uncontrolled diffusion of air-transported contaminants from the
environmental to the product during its handling.





 

Applications

·         Normally used in laboratory of microbiology and cell culture.

·         Furthermore, used in innovative fields of scientific research and above all in the manipulation of:

·         Quality Control in food industries

·         Micro mechanical assembly

·         Preparation of nutritional parenteral bags

·         IVF

Performances

Product Protection

Sterility in the working area higher than ISO 5 class according to ISO EN 14644-1 @ 0,3 and 0,5 µm particles size (Class  100/M3.5 according to Federal Standard 209E) with a laminar air flow velocity of 0,40 m/s +/-20%.

Since HELIOS is not a biosafety cabinet, it is not suitable for handling pathogens components.

Technical Specification

Working surface in stainless steel AISI 304L “2B” finishing with 15 mm lift (see picture).

Side walls in toughened safety glass with 3 holes 19 mm diameter for the easy passage of external connection of fluids and/or cables without necessity of factory assembly.

Lighting on working surface by means of 2 fluorescent lamps of 36W fitted in non-contaminated area for HELIOS 48 and 58W for HELIOS 72.

Construction structure in steel epoxy-polyester powder coated, resistant to the most common industrial disinfectants.

Ventilation system by means of n°1 motor blower for HELIOS 48 dedicated to the one-way airflow in the working chamber.

HELIOS 72 is supplied with n° 2 motor blowers in parallel way system

The motor blower is centrifugal type, direct driven motor with double aspiration and protection factor IP55.

Air filtration by means of disposable high retention capacity pre-filters and H14 HEPA filters with efficiency 99,995% MPPS according to EN 1822 (99,999% tested with DOP @ 0,3 µm).

Protection grid, for HEPA filter made by anodized aluminium.

Standard features

·         Automatic air velocity regulation

·         Fluorescent lights

·         Power socket 4 A UNEL IP 55

·         DOP/DOS 100% test inlet hose-barb port

 

Optional features

·         Steel support stand epoxy polyester coated

·         Chest of 3 drawers on pivoting wheels in steel epoxy coated

·         30W germicidal lamp with front screen, wavelength 253.7 nm (UV-C)

·         Gas manual tap manufactured in compliance with UNI/CIG regulations. Tap is provided with the automatic safety valve for interruption in case of electric blackout and/or air velocity out of pre-set range. Terminal connection for 6 mm diameter gas line.

·         Bunsen burner with automatic switch ignition

·         Bunsen burner with automatic foot switch ignition

·         Compressed air line with manual tap

·         Nitrogen line with manual tap

·         Vacuum line with manual tap