MA 50/1.X2.A.WH Moisture Analyzer , Radwag

PreviousNext
image-brand

Product order number: WL-306-0035

11.41258 RON

13.58097 RON

(VAT included)
  • Delivery in 2-4 weeks
  • Plată cu card online sau cu OP
  • 021 255 3132

Description

Moisture analysers MA 50/1.X2.A.WH

MA X2.A moisture analysers are high-tech measuring instruments for the rapid determination of relative moisture content, dry mass content and other parameters in samples of various substances. The MA.X2.A series is equipped with an innovative system: the drying chamber can be opened and closed automatically using the button or proximity sensors. This solution allows:

  •     Keeping the moisture analyser clean - the operator does not touch the moisture analyser housing.
  •     Eliminate the shock of manually closing the chamber - the chamber closes automatically and always with the same intensity.
  •     Achieve high repeatability of opening and closing the drying chamber.
  •     Increased automation of the drying process.
  •     Increased operating safety by eliminating contact with hot drying chamber components.
  •     Improved operational ergonomics.

The MA.X2.A series features a user-friendly colour touch screen. Free configuration of the control panel can be achieved via hotkeys, customisable information fields and programmable labels. The drying process can be done for any temperature and - thanks to databases - the specific drying process can be set for a specific product.

 

Strengths of the X2 series moisture analysers:

  •     Automatic opening and closing of the drying chamber
  •     5" colour capacitive touch screen
  •     Modern interface
  •     Simple and intuitive operation
  •     Programmable display
  •     Drying profiles (standard, gentle, gradual, fast)
  •     GLP/GMP print-map
  •     Repeatable and custom applications
  •     Optimised work thanks to the use of halogen lamps

 

Capacity and temperature

    Maximum capacity of MA.X2.A ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with an accuracy of 0.01% (0.001% for samples larger than 1.5g). The maximum drying temperature is 160˚C (an optional moisture analyser with a maximum temperature of 250˚C is available). An additional element to the moisture analysers that enhances their functionality is a water vapour permeability determination kit used in the tanning industry to determine the hygienic properties of leather.

   

Data bases:

    The X2 series moisture analyser information system is based on 8 databases, allowing many users to operate the product database which includes many samples. Collected measurements can be subjected to further analysis. The collected data is stored in 8 databases:

  •     Products (up to 5000 products)
  •     Users (up to 100 users)
  •     Packages (up to 100 packages)
  •     Customers (up to 1000 customers)
  •     Drying programmes (up to 200 drying programmes)
  •     Drying reports (up to 5000 drying reports)
  •     Environmental conditions (up to 10000 records)
  •     Weighing (up to 50000 records)


Results

    Results obtained using the moisture analyser (final result of the drying process):

  •     % M - mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
  •     % D - dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample remaining on the weighing pan after evaporation of moisture,
  •     % R - the ratio of moisture content to dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample which has evaporated during the drying process,
  •     g - mass of the sample after drying.

  

Interfaces

   The USB interface ensures fast transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyser. Remote access to the moisture analyser allows online data management. Cooperation with E2R allows external data management, which increases efficiency and results to the maximum.

 

DATASHEET

Metrological parameters
Capacity [Max] 50 g
Readability [d] 0.1 mg
Tare range -50 g
Adjustment external
Maximum sample weight 50 g
Heating module halogen
Moisture content repeatability +/-0.05% (sample ~ 2g), +/-0.01% (sample~ 10g)
Moisture content readability 0.0001%
Drying temperature range Max 250 °C

 

Phisycal parameters
Leveling system manual
Display colour, tactil 5”
Weighing chamber automatic
Maximum sample height 20 mm
Weighing pan dimensions ø90, h= 8 mm
Packaging dimensions 476×381×346 mm
Net weight 5.2 kg
Gross weight 6.5 kg

 

Construction
Protection class IP 43

 

Features of use
Display mod %MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC
Drying method 4 drying profiles (standard, fast, step, mild)
Finish mode 4 modes (automatic, manual, time-defined, user-defined)
Additional functions

sample traceability

 

Communication interface
Communication interface RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®

 

Electrical parameters
Power supply 100V – 120V AC 50/60Hz sau 200V-240V AC 50/60Hz
Power consumption 6 W
Heating module power 450 W

 

Environmental conditions
Operating temperature +10 — +40 °C

 

SOP metrological tests

Mass indication contro External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)
Internal adjustment

For .IC models only, GLP report

External adjustment

For all models, GLP report

Drying temperature control One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer
Moisture content indication contro

Certified MV Test Set

Adjustment Adjustment internal / external

Depending on the type of moisture analyzer, GLP report

Drying temperature adjustment Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)