Introducing our state-of-the-art ultra-sensitive thermobalance, the TG 309 Libra® Classic / Select and Supreme.
and many more fantastic features.
Analyze the unique thermal behavior of materials and their components
TG 309 Libra® Classic
The TG 309 Libra® Classic is the device with the best price-performance ratio in the Libra® series. It is the ideal instrument for Quality Control. The Classic offers a temperature range from 10 °C up to 1025 °C. In addition, it can be equipped with a 20-position ASC (Automatic Sample Changer).
Get Results Faster Without a Baseline Run
The TG 309 Libra® Select is the instrument which offers the greatest variety in the Libra® series. Temperature ranges from 10°C to 1025°C or up to 1100°C can be selected. It offers outstanding balance resolution for detecting even the smallest of changes in a material's mass. In addition, it offers the ability to couple to to gas analysis and the possibility of being equipped with a large, 204-position ASC (Automatic Sample Changer).
Get Results Faster Without a Baseline Run
To ensure accurate mass change values, a baseline run is typically conducted under test conditions that are identical in terms of heating rate, gas type, and gas flow.
The baseline takes factors such as heating rate, crucible type and geometry into account while also accounting for instrument and buoyancy effects, thus allowing these to be subtracted from the sample measurement.
The TG 309 Libra® typically eliminates the need for a separate baseline run when using the integrated BeFlat® baseline run for typical temperature measurements. This significantly speeds up tests.
To ensure accurate mass change values, a baseline run is typically conducted under test conditions that are identical in terms of heating rate, gas type, and gas flow.
The baseline takes factors such as heating rate, crucible type and geometry into account while also accounting for instrument and buoyancy effects, thus allowing these to be subtracted from the sample measurement.
The TG 309 Libra® typically eliminates the need for a separate baseline run when using the integrated BeFlat® baseline run for typical temperature measurements. This significantly speeds up tests.
The TG 309 Libra® Supreme is the top-of-the-line thermobalance in the Libra® series. It offers outstanding balance resolution for detecting even the smallest of changes in a material's mass. In addition, it offers the ability to couple to to gas analysis and the possibility of being equipped with a large, 204-position ASC (Automatic Sample Changer).
Get Results Faster Without a Baseline Run
To ensure accurate mass change values, a baseline run is typically conducted under test conditions that are identical in terms of heating rate, gas type, and gas flow.
The baseline takes factors such as heating rate, crucible type and geometry into account while also accounting for instrument and buoyancy effects, thus allowing these to be subtracted from the sample measurement.
The TG 309 Libra® typically eliminates the need for a separate baseline run when using the integrated BeFlat® baseline run for typical temperature measurements. This significantly speeds up tests.