DSC Premium 204 F1 Phoenix®

Ask for quote

0.00 RON (VAT included)
DSC Premium 204 F1 Phoenix®
Ask for advice from a consultant: +40 21 25 53 132
Ask for quote
Please fill out the following form. Attention! Fields marked with * are required!

    DSC Premium 204 F1 Phoenix®

    DSC 204 F1 Phoenix®

    The premium DSC for all requirements

    The versatile Premium Differential Scanning Calorimeter, DSC 204 F1 Phoenix®, fascinates with its unique concept: all essential operational components are integrated into the instrument and optional add-ons can be installed anytime on site.



    The DSC measuring cell consists of a cylindrical high-conductivity silver block with an embedded heating coil for broad thermal symmetry (3D symmetry) in the sample chamber, the cooling ports for liquid nitrogen or compressed air cooling and a cooling ring for connection of the intracooler (also with simultaneous liquid nitrogen cooling). The gas-tight construction and integrated mass flow controllers for the purge and protective gases allow coupling to an FT-IR or MS for gas analysis.

    Tau-sensorTau-sensor
     

    Exchangeable sensors are tailored to their tasks:

    With its disk-shaped silver carrier plate and supersensitive thermosensors of nickel-chromium constantan, the Tau-sensor offers a high level of calorimetric sensitivity along with extremely short signal time constants of only 0.6 seconds, which guarantees good separation of overlapping thermal effects.



    The µ-sensor stands out for its high level of calorimetric sensitivity, never before achieved with a Differential Scanning Calorimeter, DSC. For example, it is extremely well suited for pharmaceutical applications with small sample weights.

    µ-sensorµ-sensor
     

    Key Technical Data

    (subject to change)

    • Temperature range:

      -180°C to 700°C
    • Heating rates:

      0.001 K/min to 200 K/min
    • Cooling rates:

      max. 200 K/min
    • Compressed air cooling:

      RT to 700°C
    • Intracooler for the extended range:

      -85°C to 600°C
    • Automatically controlled LN2 cooling:

      -180°C to 700°C
    • Indium Response Ratio (*):

      >160 mW/K

      (*) Peak Height [mW]/Peak with at 50% Height [K] of Indium melting peak
    • Gas control for 2 sample gases and 1 protective gas through integrated mass flow controller and software
    • Automatic sample changer:

      for 192 samples and reference crucibles (optional)

    Reviews

    There are no reviews yet.

    Be the first to review “DSC Premium 204 F1 Phoenix®”

    Your email address will not be published. Required fields are marked *

    Shopping Cart
    Da-ți click în afară pentru a ascunde bara de comparare.
    Compare
    Scroll to Top
    This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.